CVE-2024-30212
CVSS V2 None
CVSS V3 None
Description
If a SCSI READ(10) command is initiated via USB using the largest LBA
(0xFFFFFFFF) with it's default block size of 512 and a count of 1,
the first 512 byte of the 0x80000000 memory area is returned to the
user. If the block count is increased, the full RAM can be exposed.
The same method works to write to this memory area. If RAM contains
pointers, those can be - depending on the application - overwritten to
return data from any other offset including Progam and Boot Flash.
Overview
- CVE ID
- CVE-2024-30212
- Assigner
- Microchip
- Vulnerability Status
- PUBLISHED
- Published Version
- 2024-05-28T16:07:52.946Z
- Last Modified Date
- 2024-05-28T16:07:52.946Z
Weakness Enumerations
References
Reference URL | Reference Tags |
---|---|
https://github.com/Microchip-MPLAB-Harmony/core/commit/d4608a4f1a140bd899cd4337cdbfb343a4339216 | patch mitigation |
https://github.com/Microchip-MPLAB-Harmony/core/blob/master/release_notes.md | release-notes |
https://github.com/Fehr-GmbH/blackleak |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2024-30212 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2024-30212 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2024-06-26 11:22:33 | Added to TrackCVE |