Description
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
Overview
  • CVE ID
  • CVE-2023-2071
  • Assigner
  • Rockwell
  • Vulnerability Status
  • PUBLISHED
  • Published Version
  • 2023-09-12T13:12:42.386Z
  • Last Modified Date
  • 2023-09-12T13:12:42.386Z
History
Created Old Value New Value Data Type Notes
2024-06-24 21:59:34 Added to TrackCVE