CVE-2022-41629
CVSS V2 None
CVSS V3 Critical 9.1
Description
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Overview
- CVE ID
- CVE-2022-41629
- Assigner
- ics-cert@hq.dhs.gov
- Vulnerability Status
- Analyzed
- Published Version
- 2022-10-31T20:15:13
- Last Modified Date
- 2022-11-02T12:59:49
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:* | 1 | OR | 00.00.02a |
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- HIGH
- Availability Impact
- NONE
- Base Score
- 9.1
- Base Severity
- CRITICAL
- Exploitability Score
- 3.9
- Impact Score
- 5.2
References
Reference URL | Reference Tags |
---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2022-41629 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-41629 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-10-31 21:00:06 | Added to TrackCVE | |||
2022-12-07 15:11:04 | 2022-10-31T20:15Z | 2022-10-31T20:15:13 | CVE Published Date | updated |
2022-12-07 15:11:04 | 2022-11-02T12:59:49 | CVE Modified Date | updated | |