CVE-2022-31206

CVSS V2 None CVSS V3 Critical 9.8
Description
The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS.
Overview
  • CVE ID
  • CVE-2022-31206
  • Assigner
  • cve@mitre.org
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2022-07-26T22:15:11
  • Last Modified Date
  • 2022-08-04T15:01:04
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:omron:nx701-1600_firmware:*:*:*:*:*:*:*:* 1 OR 1.29
cpe:2.3:h:omron:nx701-1600:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nx701-1620_firmware:*:*:*:*:*:*:*:* 1 OR 1.29
cpe:2.3:h:omron:nx701-1620:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nx701-1700_firmware:*:*:*:*:*:*:*:* 1 OR 1.29
cpe:2.3:h:omron:nx701-1700:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nx701-1720_firmware:*:*:*:*:*:*:*:* 1 OR 1.29
cpe:2.3:h:omron:nx701-1720:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nx701-z600_firmware:*:*:*:*:*:*:*:* 1 OR 1.29
cpe:2.3:h:omron:nx701-z600:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nx701-z700_firmware:*:*:*:*:*:*:*:* 1 OR 1.29
cpe:2.3:h:omron:nx701-z700:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj101-1000_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj101-1000:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj101-1020_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj101-1020:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj101-9000_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj101-9000:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj101-9020_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj101-9020:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj301-1100_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj301-1100:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj301-1200_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj301-1200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1300_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1300:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1320_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1320:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1340_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1340:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1400_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1400:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1420_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1420:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1500_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1500:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-1520_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-1520:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-4300_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-4300:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-4320_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-4320:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-4400_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-4400:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-4500_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-4500:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-5300_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-5300:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:omron:nj501-5300-1_firmware:*:*:*:*:*:*:*:* 1 OR 1.49
cpe:2.3:h:omron:nj501-5300-1:-:*:*:*:*:*:*:* 0 OR
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • HIGH
  • Availability Impact
  • HIGH
  • Base Score
  • 9.8
  • Base Severity
  • CRITICAL
  • Exploitability Score
  • 3.9
  • Impact Score
  • 5.9
History
Created Old Value New Value Data Type Notes
2022-07-26 23:00:26 Added to TrackCVE