CVE-2022-26334
CVSS V2 High 7.8
CVSS V3 High 7.5
Description
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
Overview
- CVE ID
- CVE-2022-26334
- Assigner
- productcert@siemens.com
- Vulnerability Status
- Analyzed
- Published Version
- 2022-04-12T09:15:14
- Last Modified Date
- 2022-04-19T18:14:00
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2lh\+_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x308-2lh\+:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:* | 1 | OR | 4.1.4 | |
cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:L/Au:N/C:N/I:N/A:C
- Access Vector
- NETWORK
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- NONE
- Integrity Impact
- NONE
- Availability Impact
- COMPLETE
- Base Score
- 7.8
- Severity
- HIGH
- Exploitability Score
- 10
- Impact Score
- 6.9
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- NONE
- Availability Impact
- HIGH
- Base Score
- 7.5
- Base Severity
- HIGH
- Exploitability Score
- 3.9
- Impact Score
- 3.6
References
Reference URL | Reference Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf | Mitigation Patch Vendor Advisory |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2022-26334 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-26334 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-04-20 17:01:34 | Added to TrackCVE |