CVE-2022-22808

CVSS V2 Medium 6.8 CVSS V3 High 8.8
Description
A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
Overview
  • CVE ID
  • CVE-2022-22808
  • Assigner
  • cybersecurity@se.com
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2022-02-09T23:15:19
  • Last Modified Date
  • 2023-02-02T18:50:45
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:schneider-electric:hmibscea53d1edb_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1edb:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1eds_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1eds:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1edm_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1edm:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1edl_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1edl:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1ess_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1ess:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1esm_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1esm:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1eml_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1eml:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:M/Au:N/C:P/I:P/A:P
  • Access Vector
  • NETWORK
  • Access Compatibility
  • MEDIUM
  • Authentication
  • NONE
  • Confidentiality Impact
  • PARTIAL
  • Integrity Impact
  • PARTIAL
  • Availability Impact
  • PARTIAL
  • Base Score
  • 6.8
  • Severity
  • MEDIUM
  • Exploitability Score
  • 8.6
  • Impact Score
  • 6.4
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • REQUIRED
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • HIGH
  • Availability Impact
  • HIGH
  • Base Score
  • 8.8
  • Base Severity
  • HIGH
  • Exploitability Score
  • 2.8
  • Impact Score
  • 5.9
References
Reference URL Reference Tags
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-02 Patch Vendor Advisory
History
Created Old Value New Value Data Type Notes
2022-05-10 06:32:32 Added to TrackCVE
2022-12-06 09:17:53 cybersecurity@schneider-electric.com cybersecurity@se.com CVE Assigner updated
2022-12-06 09:17:53 2022-02-09T23:15Z 2022-02-09T23:15:19 CVE Published Date updated
2022-12-06 09:17:53 2022-11-10T22:15:12 CVE Modified Date updated
2022-12-06 09:17:53 Undergoing Analysis Vulnerability Status updated
2023-02-02 19:12:44 2023-02-02T18:50:45 CVE Modified Date updated