CVE-2022-22807

CVSS V2 Medium 4.3 CVSS V3 High 7.4
Description
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
Overview
  • CVE ID
  • CVE-2022-22807
  • Assigner
  • cybersecurity@se.com
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2022-02-09T23:15:19
  • Last Modified Date
  • 2023-02-22T17:54:21
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:schneider-electric:hmibscea53d1edb_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1edb:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1eds_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1eds:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1edm_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1edm:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1edl_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1edl:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1ess_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1ess:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1esm_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1esm:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:hmibscea53d1eml_firmware:*:*:*:*:*:*:*:* 1 OR 4.0.0.13
cpe:2.3:h:schneider-electric:hmibscea53d1eml:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:a:cisco:expressway:*:*:*:*:*:*:*:* 1 OR 14.0.7
cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:expressway:*:*:* 1 OR x14.0.7
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:M/Au:N/C:N/I:P/A:N
  • Access Vector
  • NETWORK
  • Access Compatibility
  • MEDIUM
  • Authentication
  • NONE
  • Confidentiality Impact
  • NONE
  • Integrity Impact
  • PARTIAL
  • Availability Impact
  • NONE
  • Base Score
  • 4.3
  • Severity
  • MEDIUM
  • Exploitability Score
  • 8.6
  • Impact Score
  • 2.9
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • REQUIRED
  • Scope
  • CHANGED
  • Confidentiality Impact
  • NONE
  • Availability Impact
  • NONE
  • Base Score
  • 7.4
  • Base Severity
  • HIGH
  • Exploitability Score
  • 2.8
  • Impact Score
  • 4
History
Created Old Value New Value Data Type Notes
2022-05-10 06:32:31 Added to TrackCVE
2022-12-06 09:17:48 cybersecurity@schneider-electric.com cybersecurity@se.com CVE Assigner updated
2022-12-06 09:17:48 2022-02-09T23:15Z 2022-02-09T23:15:19 CVE Published Date updated
2022-12-06 09:17:48 2022-09-10T02:41:39 CVE Modified Date updated
2022-12-06 09:17:48 Analyzed Vulnerability Status updated
2022-12-06 09:17:53 References updated
2023-01-17 18:39:23 2023-01-17T16:15:16 CVE Modified Date updated
2023-01-17 18:39:23 Analyzed Modified Vulnerability Status updated
2023-01-18 15:13:27 Modified Undergoing Analysis Vulnerability Status updated
2023-02-22 19:13:11 2023-02-22T17:54:21 CVE Modified Date updated
2023-02-22 19:13:11 Undergoing Analysis Analyzed Vulnerability Status updated