CVE-2022-22805

CVSS V2 High 7.5 CVSS V3 Critical 9.8
Description
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
Overview
  • CVE ID
  • CVE-2022-22805
  • Assigner
  • cybersecurity@se.com
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2022-03-09T20:15:08
  • Last Modified Date
  • 2022-05-12T20:42:10
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:* 1 OR 04.5
cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:* 1 OR 04.2
cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:* 1 OR 02.9
cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:* 1 OR 02.5
cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:* 1 OR 02.5
cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:* 1 OR 02.5
cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:* 1 OR 03.1
cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:* 1 OR 03.1
cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:L/Au:N/C:P/I:P/A:P
  • Access Vector
  • NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • NONE
  • Confidentiality Impact
  • PARTIAL
  • Integrity Impact
  • PARTIAL
  • Availability Impact
  • PARTIAL
  • Base Score
  • 7.5
  • Severity
  • HIGH
  • Exploitability Score
  • 10
  • Impact Score
  • 6.4
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • HIGH
  • Availability Impact
  • HIGH
  • Base Score
  • 9.8
  • Base Severity
  • CRITICAL
  • Exploitability Score
  • 3.9
  • Impact Score
  • 5.9
References
History
Created Old Value New Value Data Type Notes
2022-05-10 15:43:09 Added to TrackCVE
2022-12-06 11:38:38 cybersecurity@schneider-electric.com cybersecurity@se.com CVE Assigner updated
2022-12-06 11:38:38 2022-03-09T20:15Z 2022-03-09T20:15:08 CVE Published Date updated
2022-12-06 11:38:38 2022-05-12T20:42:10 CVE Modified Date updated
2022-12-06 11:38:38 Analyzed Vulnerability Status updated