CVE-2022-22805
CVSS V2 High 7.5
CVSS V3 Critical 9.8
Description
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
Overview
- CVE ID
- CVE-2022-22805
- Assigner
- cybersecurity@se.com
- Vulnerability Status
- Analyzed
- Published Version
- 2022-03-09T20:15:08
- Last Modified Date
- 2022-05-12T20:42:10
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:o:schneider-electric:smt_series_1015_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 04.5 | |
cpe:2.3:h:schneider-electric:smt_series_1015_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:smc_series_1018_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 04.2 | |
cpe:2.3:h:schneider-electric:smc_series_1018_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:smtl_series_1026_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 02.9 | |
cpe:2.3:h:schneider-electric:smtl_series_1026_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:scl_series_1029_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 02.5 | |
cpe:2.3:h:schneider-electric:scl_series_1029_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:scl_series_1030_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 02.5 | |
cpe:2.3:h:schneider-electric:scl_series_1030_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:scl_series_1036_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 02.5 | |
cpe:2.3:h:schneider-electric:scl_series_1036_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:scl_series_1037_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 03.1 | |
cpe:2.3:h:schneider-electric:scl_series_1037_ups:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:smx_series_1031_ups_firmware:*:*:*:*:*:*:*:* | 1 | OR | 03.1 | |
cpe:2.3:h:schneider-electric:smx_series_1031_ups:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:L/Au:N/C:P/I:P/A:P
- Access Vector
- NETWORK
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- PARTIAL
- Integrity Impact
- PARTIAL
- Availability Impact
- PARTIAL
- Base Score
- 7.5
- Severity
- HIGH
- Exploitability Score
- 10
- Impact Score
- 6.4
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- HIGH
- Availability Impact
- HIGH
- Base Score
- 9.8
- Base Severity
- CRITICAL
- Exploitability Score
- 3.9
- Impact Score
- 5.9
References
Reference URL | Reference Tags |
---|---|
https://www.se.com/ww/en/download/document/SEVD-2022-067-02/ |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2022-22805 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-22805 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 15:43:09 | Added to TrackCVE | |||
2022-12-06 11:38:38 | cybersecurity@schneider-electric.com | cybersecurity@se.com | CVE Assigner | updated |
2022-12-06 11:38:38 | 2022-03-09T20:15Z | 2022-03-09T20:15:08 | CVE Published Date | updated |
2022-12-06 11:38:38 | 2022-05-12T20:42:10 | CVE Modified Date | updated | |
2022-12-06 11:38:38 | Analyzed | Vulnerability Status | updated |