CVE-2021-31883
CVSS V2 Medium 5
CVSS V3 High 7.5
Description
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
Overview
- CVE ID
- CVE-2021-31883
- Assigner
- productcert@siemens.com
- Vulnerability Status
- Modified
- Published Version
- 2021-11-09T12:15:09
- Last Modified Date
- 2022-05-20T13:15:12
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* | 1 | OR | 2017.02.1 | |
cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:* | 1 | OR | ||
AND | ||||
cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:L/Au:N/C:N/I:N/A:P
- Access Vector
- NETWORK
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- NONE
- Integrity Impact
- NONE
- Availability Impact
- PARTIAL
- Base Score
- 5
- Severity
- MEDIUM
- Exploitability Score
- 10
- Impact Score
- 2.9
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- NONE
- Availability Impact
- HIGH
- Base Score
- 7.5
- Base Severity
- HIGH
- Exploitability Score
- 3.9
- Impact Score
- 3.6
References
Reference URL | Reference Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2021-31883 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-31883 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 15:43:39 | Added to TrackCVE | |||
2022-12-05 14:06:50 | 2021-11-09T12:15Z | 2021-11-09T12:15:09 | CVE Published Date | updated |
2022-12-05 14:06:50 | 2022-05-20T13:15:12 | CVE Modified Date | updated | |
2022-12-05 14:06:50 | Modified | Vulnerability Status | updated |