CVE-2021-22778
CVSS V2 Low 3.6
CVSS V3 High 7.1
Description
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
Overview
- CVE ID
- CVE-2021-22778
- Assigner
- cybersecurity@se.com
- Vulnerability Status
- Analyzed
- Published Version
- 2021-07-14T15:15:08
- Last Modified Date
- 2021-07-26T12:59:19
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:* | 1 | OR | 15.0 | |
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:* | 1 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:L/AC:L/Au:N/C:P/I:P/A:N
- Access Vector
- LOCAL
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- PARTIAL
- Integrity Impact
- PARTIAL
- Availability Impact
- NONE
- Base Score
- 3.6
- Severity
- LOW
- Exploitability Score
- 3.9
- Impact Score
- 4.9
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Attack Vector
- LOCAL
- Attack Compatibility
- LOW
- Privileges Required
- LOW
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- HIGH
- Availability Impact
- NONE
- Base Score
- 7.1
- Base Severity
- HIGH
- Exploitability Score
- 1.8
- Impact Score
- 5.2
References
Reference URL | Reference Tags |
---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 | Vendor Advisory |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2021-22778 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-22778 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 15:52:59 | Added to TrackCVE | |||
2022-12-05 06:06:07 | cybersecurity@schneider-electric.com | cybersecurity@se.com | CVE Assigner | updated |
2022-12-05 06:06:07 | 2021-07-14T15:15Z | 2021-07-14T15:15:08 | CVE Published Date | updated |
2022-12-05 06:06:07 | 2021-07-26T12:59:19 | CVE Modified Date | updated | |
2022-12-05 06:06:07 | Analyzed | Vulnerability Status | updated |