CVE-2021-22706
CVSS V2 Medium 4.3
CVSS V3 Medium 6.1
Description
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
Overview
- CVE ID
- CVE-2021-22706
- Assigner
- cybersecurity@se.com
- Vulnerability Status
- Analyzed
- Published Version
- 2021-07-21T15:15:14
- Last Modified Date
- 2021-07-27T20:39:13
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:* | 1 | OR | r8_v3.4.0.1 | |
cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:* | 1 | OR | r8_v3.4.0.1 | |
cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:* | 1 | OR | r8_v3.4.0.1 | |
cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:* | 1 | OR | r8_v3.4.0.1 | |
cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:* | 1 | OR | r8_v3.4.0.1 | |
cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:* | 1 | OR | r8_v3.4.0.1 | |
cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:M/Au:N/C:N/I:P/A:N
- Access Vector
- NETWORK
- Access Compatibility
- MEDIUM
- Authentication
- NONE
- Confidentiality Impact
- NONE
- Integrity Impact
- PARTIAL
- Availability Impact
- NONE
- Base Score
- 4.3
- Severity
- MEDIUM
- Exploitability Score
- 8.6
- Impact Score
- 2.9
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- REQUIRED
- Scope
- CHANGED
- Confidentiality Impact
- LOW
- Availability Impact
- NONE
- Base Score
- 6.1
- Base Severity
- MEDIUM
- Exploitability Score
- 2.8
- Impact Score
- 2.7
References
Reference URL | Reference Tags |
---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06 | Vendor Advisory |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2021-22706 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-22706 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 15:52:43 | Added to TrackCVE | |||
2022-12-05 06:33:58 | cybersecurity@schneider-electric.com | cybersecurity@se.com | CVE Assigner | updated |
2022-12-05 06:33:58 | 2021-07-21T15:15Z | 2021-07-21T15:15:14 | CVE Published Date | updated |
2022-12-05 06:33:58 | 2021-07-27T20:39:13 | CVE Modified Date | updated | |
2022-12-05 06:33:58 | Analyzed | Vulnerability Status | updated |