CVE-2021-22283

CVSS V2 None CVSS V3 None
Description
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
Overview
  • CVE ID
  • CVE-2021-22283
  • Assigner
  • cybersecurity@ch.abb.com
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2023-02-28T05:15:12
  • Last Modified Date
  • 2023-03-13T16:07:23
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:abb:smu615_firmware:*:*:*:*:*:*:*:* 1 OR 1.0.2
cpe:2.3:h:abb:smu615:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:rec615_firmware:*:*:*:*:*:*:*:* 1 OR 2.0.3
cpe:2.3:h:abb:rec615:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:rer615_firmware:*:*:*:*:*:*:*:* 1 OR 2.0.3
cpe:2.3:h:abb:rer615:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:evd4_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:evd4:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:ref615r_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:ref615r:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:rex640_pcl3_firmware:*:*:*:*:*:*:*:* 1 OR 1.2.1
cpe:2.3:h:abb:rex640_pcl3:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:rex640_pcl2_firmware:*:*:*:*:*:*:*:* 1 OR 1.1.4
cpe:2.3:h:abb:rex640_pcl2:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:rex640_pcl1_firmware:*:*:*:*:*:*:*:* 1 OR 1.0.8
cpe:2.3:h:abb:rex640_pcl1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:rer620_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:rer620:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_611_firmware:*:*:*:*:*:*:*:* 1 OR 2.0.3
cpe:2.3:h:abb:relion_611:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:ref615_iec_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:ref615_iec:1.0:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:ref615_ansi_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:ref615_ansi:1.0:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:ref615_iec_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:ref615_iec:1.1:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:red615_iec_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:red615_iec:1.1:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:ref615_ansi_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:ref615_ansi:1.1:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:relion_615_iec:2.0:*:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_iec:3.0:*:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_iec:4.0:-:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_cn_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:relion_615_cn:2.0:*:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_cn:3.0:*:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_cn:3.1:*:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_cn:4.0:-:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_cn:5.0:fp1:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_ansi_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:relion_615_ansi:2.0:*:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_ansi:4.0:-:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_ansi:4.0:fp1:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_ansi:4.0:fp2:*:*:*:*:*:* 0 OR
cpe:2.3:h:abb:relion_615_ansi:5.0:fp1:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:* 1 OR 4.1.9
cpe:2.3:h:abb:relion_615_iec:4.0:fp1:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_cn_firmware:*:*:*:*:*:*:*:* 1 OR 4.1.8
cpe:2.3:h:abb:relion_615_cn:4.0:fp1:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:* 1 OR 5.0.12
cpe:2.3:h:abb:relion_615_iec:5.0:-:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:* 1 OR 5.1.20
cpe:2.3:h:abb:relion_615_iec:5.0:fp1:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_620_iec_firmware:*:*:*:*:*:*:*:* 1 OR 2.0.11
cpe:2.3:h:abb:relion_620_iec:2.0:-:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_620_cn_firmware:*:*:*:*:*:*:*:* 1 OR 2.0.11
cpe:2.3:h:abb:relion_620_cn:2.0:-:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_620_ansi_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:abb:relion_620_ansi:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_620_iec_firmware:*:*:*:*:*:*:*:* 1 OR 2.1.15
cpe:2.3:h:abb:relion_620_iec:2.0:fp1:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:abb:relion_620_cn_firmware:*:*:*:*:*:*:*:* 1 OR 2.1.15
cpe:2.3:h:abb:relion_620_cn:2.0:fp1:*:*:*:*:*:* 0 OR
History
Created Old Value New Value Data Type Notes
2023-04-17 05:39:20 Added to TrackCVE
2023-04-17 05:39:23 Weakness Enumeration new