CVE-2021-20587
CVSS V2 High 7.5
CVSS V3 Critical 9.8
Description
Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.
Overview
- CVE ID
- CVE-2021-20587
- Assigner
- Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp
- Vulnerability Status
- Modified
- Published Version
- 2021-02-19T20:15:12
- Last Modified Date
- 2022-11-18T05:15:11
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:*:*:*:*:*:*:*:* | 1 | OR | 1.112r | |
cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:* | 1 | OR | 1.011m | |
cpe:2.3:a:mitsubishielectric:data_transfer:*:*:*:*:*:*:*:* | 1 | OR | 3.44w | |
cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:* | 1 | OR | 1.24a | |
cpe:2.3:a:mitsubishielectric:gt_designer3:*:*:*:*:*:*:*:* | 1 | OR | 1.250l | |
cpe:2.3:a:mitsubishielectric:gt_softgot1000:*:*:*:*:*:*:*:* | 1 | OR | 3.245f | |
cpe:2.3:a:mitsubishielectric:gt_softgot2000:*:*:*:*:*:*:*:* | 1 | OR | 1.250l | |
cpe:2.3:a:mitsubishielectric:gx_configurator-dp:*:*:*:*:*:*:*:* | 1 | OR | 7.14q | |
cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:gx_developer:*:*:*:*:*:*:*:* | 1 | OR | 8.506c | |
cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:gx_logviewer:*:*:*:*:*:*:*:* | 1 | OR | 1.115u | |
cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:* | 1 | OR | 1.597x | |
cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:* | 1 | OR | 1.070y | |
cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:melfa-works:*:*:*:*:*:*:*:* | 1 | OR | 4.4 | |
cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:* | 1 | OR | 2.74c | |
cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:*:*:*:*:*:*:*:* | 1 | OR | 2.004e | |
cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:* | 1 | OR | 1.167z | |
cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:* | 1 | OR | 5.001b | |
cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:px_developer:*:*:*:*:*:*:*:* | 1 | OR | 1.53f | |
cpe:2.3:a:mitsubishielectric:rt_toolbox2:*:*:*:*:*:*:*:* | 1 | OR | 3.73b | |
cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:* | 1 | OR | 1.82l | |
cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:mitsubishielectric:slmp_data_collector:*:*:*:*:*:*:*:* | 1 | OR | 1.04e |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:L/Au:N/C:P/I:P/A:P
- Access Vector
- NETWORK
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- PARTIAL
- Integrity Impact
- PARTIAL
- Availability Impact
- PARTIAL
- Base Score
- 7.5
- Severity
- HIGH
- Exploitability Score
- 10
- Impact Score
- 6.4
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- HIGH
- Availability Impact
- HIGH
- Base Score
- 9.8
- Base Severity
- CRITICAL
- Exploitability Score
- 3.9
- Impact Score
- 5.9
References
Reference URL | Reference Tags |
---|---|
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-021_en.pdf | Vendor Advisory |
https://jvn.jp/vu/JVNVU92330101/index.html | Third Party Advisory |
https://us-cert.cisa.gov/ics/advisories/icsa-21-049-02 |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2021-20587 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-20587 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 06:33:22 | Added to TrackCVE | |||
2022-12-05 22:25:51 | 2021-02-19T20:15Z | 2021-02-19T20:15:12 | CVE Published Date | updated |
2022-12-05 22:25:51 | 2022-11-18T05:15:11 | CVE Modified Date | updated | |
2022-12-05 22:25:51 | Modified | Vulnerability Status | updated |