CVE-2020-7581
CVSS V2 High 7.2
CVSS V3 Medium 6.7
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
Overview
- CVE ID
- CVE-2020-7581
- Assigner
- productcert@siemens.com
- Vulnerability Status
- Analyzed
- Published Version
- 2020-07-14T14:15:18
- Last Modified Date
- 2023-01-30T19:54:07
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:* | 1 | OR | 3.2 | |
cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:* | 1 | OR | 3.2 | |
cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:* | 1 | OR | 3.2 | |
cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:* | 1 | OR | 11.3 | |
cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:* | 1 | OR | ||
cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:* | 1 | OR | 16 | |
cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:* | 1 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:L/AC:L/Au:N/C:C/I:C/A:C
- Access Vector
- LOCAL
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- COMPLETE
- Integrity Impact
- COMPLETE
- Availability Impact
- COMPLETE
- Base Score
- 7.2
- Severity
- HIGH
- Exploitability Score
- 3.9
- Impact Score
- 10
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Attack Vector
- LOCAL
- Attack Compatibility
- LOW
- Privileges Required
- HIGH
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- HIGH
- Availability Impact
- HIGH
- Base Score
- 6.7
- Base Severity
- MEDIUM
- Exploitability Score
- 0.8
- Impact Score
- 5.9
References
Reference URL | Reference Tags |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | Vendor Advisory |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2020-7581 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-7581 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 07:07:27 | Added to TrackCVE | |||
2022-12-04 19:26:35 | 2020-07-14T14:15Z | 2020-07-14T14:15:18 | CVE Published Date | updated |
2022-12-04 19:26:35 | 2022-08-10T12:25:58 | CVE Modified Date | updated | |
2022-12-04 19:26:35 | Undergoing Analysis | Vulnerability Status | updated | |
2023-01-30 21:09:45 | 2023-01-30T19:54:07 | CVE Modified Date | updated | |
2023-01-30 21:09:45 | Undergoing Analysis | Analyzed | Vulnerability Status | updated |