CVE-2019-6807
CVSS V2 Medium 5
CVSS V3 High 7.5
Description
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus.
Overview
- CVE ID
- CVE-2019-6807
- Assigner
- cybersecurity@se.com
- Vulnerability Status
- Analyzed
- Published Version
- 2019-05-22T21:29:00
- Last Modified Date
- 2022-02-03T14:26:07
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.10 | |
cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:* | 1 | OR | 2.90 | |
cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:L/Au:N/C:N/I:N/A:P
- Access Vector
- NETWORK
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- NONE
- Integrity Impact
- NONE
- Availability Impact
- PARTIAL
- Base Score
- 5
- Severity
- MEDIUM
- Exploitability Score
- 10
- Impact Score
- 2.9
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- NONE
- Availability Impact
- HIGH
- Base Score
- 7.5
- Base Severity
- HIGH
- Exploitability Score
- 3.9
- Impact Score
- 3.6
References
Reference URL | Reference Tags |
---|---|
https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/ | Mitigation Vendor Advisory |
https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0770 | Exploit Third Party Advisory |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2019-6807 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-6807 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 06:34:34 | Added to TrackCVE | |||
2022-12-03 21:08:22 | cybersecurity@schneider-electric.com | cybersecurity@se.com | CVE Assigner | updated |
2022-12-03 21:08:22 | 2019-05-22T21:29Z | 2019-05-22T21:29:00 | CVE Published Date | updated |
2022-12-03 21:08:22 | 2022-02-03T14:26:07 | CVE Modified Date | updated | |
2022-12-03 21:08:22 | Analyzed | Vulnerability Status | updated |