CVE-2019-6575

CVSS V2 High 7.8 CVSS V3 High 7.5
Description
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
Overview
  • CVE ID
  • CVE-2019-6575
  • Assigner
  • productcert@siemens.com
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2019-04-17T14:29:03
  • Last Modified Date
  • 2022-10-06T16:40:43
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* 1 OR 2.7
cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:* 1 OR 2.5
cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* 1 OR 2.5
cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:* 1 OR 3.15-p018
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:* 1 OR 1.0
cpe:2.3:a:siemens:sinec-nms:1.0:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:* 1 OR 2.1
cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:* 1 OR 3.1.1
AND
cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:* 1 OR 2.5
cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:* 1 OR 2.5
cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:* 1 OR 2.5
cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* 1 OR 15.1
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* 1 OR 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* 1 OR 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* 1 OR 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* 1 OR 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* 1 OR 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:* 1 OR
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:L/Au:N/C:N/I:N/A:C
  • Access Vector
  • NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • NONE
  • Confidentiality Impact
  • NONE
  • Integrity Impact
  • NONE
  • Availability Impact
  • COMPLETE
  • Base Score
  • 7.8
  • Severity
  • HIGH
  • Exploitability Score
  • 10
  • Impact Score
  • 6.9
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • NONE
  • Availability Impact
  • HIGH
  • Base Score
  • 7.5
  • Base Severity
  • HIGH
  • Exploitability Score
  • 3.9
  • Impact Score
  • 3.6
References
Reference URL Reference Tags
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf Vendor Advisory
History
Created Old Value New Value Data Type Notes
2022-05-10 15:43:35 Added to TrackCVE
2022-12-03 19:38:35 2019-04-17T14:29Z 2019-04-17T14:29:03 CVE Published Date updated
2022-12-03 19:38:35 2022-10-06T16:40:43 CVE Modified Date updated
2022-12-03 19:38:35 Analyzed Vulnerability Status updated