CVE-2019-19282

CVSS V2 High 7.1 CVSS V3 High 7.5
Description
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.
Overview
  • CVE ID
  • CVE-2019-19282
  • Assigner
  • productcert@siemens.com
  • Vulnerability Status
  • Modified
  • Published Version
  • 2020-03-10T20:15:18
  • Last Modified Date
  • 2023-04-11T10:15:08
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
cpe:2.3:a:siemens:openpcs_7:9.0:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:openpcs_7:9.0_update_1:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_batch:9.0:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_batch:9.0:sp1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_2:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_3:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_4:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:* 1 OR 16
cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_pcs_7:9.0:sp1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_pcs_7:9.0:sp2:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:* 1 OR 9.0
cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_10:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_11:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_12:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_13:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_2:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_3:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_4:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_5:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_6:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_7:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_8:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_9:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:-:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:7.5.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:13:sp1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:14.0.1:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:* 1 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:M/Au:N/C:N/I:N/A:C
  • Access Vector
  • NETWORK
  • Access Compatibility
  • MEDIUM
  • Authentication
  • NONE
  • Confidentiality Impact
  • NONE
  • Integrity Impact
  • NONE
  • Availability Impact
  • COMPLETE
  • Base Score
  • 7.1
  • Severity
  • HIGH
  • Exploitability Score
  • 8.6
  • Impact Score
  • 6.9
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • NONE
  • Availability Impact
  • HIGH
  • Base Score
  • 7.5
  • Base Severity
  • HIGH
  • Exploitability Score
  • 3.9
  • Impact Score
  • 3.6
References
Reference URL Reference Tags
https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf Vendor Advisory
History
Created Old Value New Value Data Type Notes
2022-05-10 15:43:36 Added to TrackCVE
2022-12-04 12:19:49 2020-03-10T20:15Z 2020-03-10T20:15:18 CVE Published Date updated
2022-12-04 12:19:49 2022-04-12T10:15:10 CVE Modified Date updated
2022-12-04 12:19:49 Modified Vulnerability Status updated
2023-04-11 14:08:32 2023-04-11T10:15:08 CVE Modified Date updated
2023-04-11 14:08:33 Weakness Enumeration update
2023-04-11 14:08:33 A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction. A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction. Description updated