CVE-2019-15681
CVSS V2 Medium 5
CVSS V3 High 7.5
Description
LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a.
Overview
- CVE ID
- CVE-2019-15681
- Assigner
- vulnerability@kaspersky.com
- Vulnerability Status
- Analyzed
- Published Version
- 2019-10-29T19:15:18
- Last Modified Date
- 2022-04-05T21:10:02
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:a:libvnc_project:libvncserver:*:*:*:*:*:*:*:* | 1 | OR | 0.9.12 | |
AND | ||||
cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:lts:*:*:* | 1 | OR | ||
cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:* | 1 | OR | ||
cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:* | 1 | OR | ||
cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:* | 1 | OR | ||
cpe:2.3:o:canonical:ubuntu_linux:18.10:*:*:*:*:*:*:* | 1 | OR | ||
AND | ||||
cpe:2.3:o:debian:debian_linux:8.0:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:* | 1 | OR | ||
AND | ||||
cpe:2.3:o:siemens:simatic_itc1500_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.0.0.0 | 3.2.1.0 |
cpe:2.3:h:siemens:simatic_itc1500:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:simatic_itc1500_pro_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.0.0.0 | 3.2.1.0 |
cpe:2.3:h:siemens:simatic_itc1500_pro:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:simatic_itc1900_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.0.0.0 | 3.2.1.0 |
cpe:2.3:h:siemens:simatic_itc1900:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:simatic_itc1900_pro_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.0.0.0 | 3.2.1.0 |
cpe:2.3:h:siemens:simatic_itc1900_pro:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:simatic_itc2200_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.0.0.0 | 3.2.1.0 |
cpe:2.3:h:siemens:simatic_itc2200:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:siemens:simatic_itc2200_pro_firmware:*:*:*:*:*:*:*:* | 1 | OR | 3.0.0.0 | 3.2.1.0 |
cpe:2.3:h:siemens:simatic_itc2200_pro:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:N/AC:L/Au:N/C:P/I:N/A:N
- Access Vector
- NETWORK
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- PARTIAL
- Integrity Impact
- NONE
- Availability Impact
- NONE
- Base Score
- 5
- Severity
- MEDIUM
- Exploitability Score
- 10
- Impact Score
- 2.9
CVSS Version 3
- Version
- 3.1
- Vector String
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Attack Vector
- NETWORK
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- HIGH
- Availability Impact
- NONE
- Base Score
- 7.5
- Base Severity
- HIGH
- Exploitability Score
- 3.9
- Impact Score
- 3.6
References
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2019-15681 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-15681 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 06:29:39 | Added to TrackCVE | |||
2022-12-04 05:08:42 | 2019-10-29T19:15Z | 2019-10-29T19:15:18 | CVE Published Date | updated |
2022-12-04 05:08:42 | 2022-04-05T21:10:02 | CVE Modified Date | updated | |
2022-12-04 05:08:42 | Analyzed | Vulnerability Status | updated |