** DISPUTED ** On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover a data value. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: the vendor's position is that there is no security impact: the only potentially leaked information is the number of characters in the PIN.
Overview
- CVE ID
- CVE-2019-14359
- Assigner
- cve@mitre.org
- Vulnerability Status
- Analyzed
- Published Version
- 2019-08-12T23:15:11
- Last Modified Date
- 2021-07-21T11:39:23
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:o:real-sec:bc_vault_firmware:-:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:real-sec:bc_vault:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:L/AC:L/Au:N/C:P/I:N/A:N
- Access Vector
- LOCAL
- Access Compatibility
- LOW
- Authentication
- NONE
- Confidentiality Impact
- PARTIAL
- Integrity Impact
- NONE
- Availability Impact
- NONE
- Base Score
- 2.1
- Severity
- LOW
- Exploitability Score
- 3.9
- Impact Score
- 2.9
CVSS Version 3
- Version
- 3.0
- Vector String
- CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Attack Vector
- PHYSICAL
- Attack Compatibility
- LOW
- Privileges Required
- NONE
- User Interaction
- NONE
- Scope
- UNCHANGED
- Confidentiality Impact
- LOW
- Availability Impact
- NONE
- Base Score
- 2.4
- Base Severity
- LOW
- Exploitability Score
- 0.9
- Impact Score
- 1.4
References
Reference URL | Reference Tags |
---|---|
https://bc-vault.com/2019/08/our-response-to-cve-2019-14359 | Exploit Third Party Advisory |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2019-14359 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2019-14359 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 16:09:28 | Added to TrackCVE | |||
2022-12-04 00:58:51 | 2019-08-12T23:15Z | 2019-08-12T23:15:11 | CVE Published Date | updated |
2022-12-04 00:58:51 | 2021-07-21T11:39:23 | CVE Modified Date | updated | |
2022-12-04 00:58:51 | Analyzed | Vulnerability Status | updated |