CVE-2019-13946

CVSS V2 High 7.8 CVSS V3 High 7.5
Description
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Overview
  • CVE ID
  • CVE-2019-13946
  • Assigner
  • productcert@siemens.com
  • Vulnerability Status
  • Modified
  • Published Version
  • 2020-02-11T16:15:15
  • Last Modified Date
  • 2023-04-11T10:15:08
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:a:siemens:dk_standard_ethernet_controller:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:a:siemens:profinet_driver:*:*:*:*:*:*:*:* 1 OR 2.1
cpe:2.3:a:siemens:simatic_ipc_support:*:*:*:*:*:*:*:* 1 OR
AND
cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:* 1 OR 4.5
cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:* 1 OR 4.6
cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:* 1 OR 4.3
cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:* 1 OR 4.3
cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:* 1 OR 4.3
cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:* 1 OR 6.0.1
cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:scalance_xf-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:* 1 OR 5.3
cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_x-400_firmware:*:*:*:*:*:*:*:* 1 OR 6.0
cpe:2.3:h:siemens:scalance_x-400:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:* 1 OR 6.0
cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:* 1 OR 6.0
cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:* 1 OR 6.0
cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:* 1 OR 6.0
cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:* 1 OR 6.0
cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:* 1 OR 2.8
cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:* 1 OR 2.8
cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_343-1_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_343-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_343-1_advanced_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_343-1_advanced:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_343-1_erpc_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_343-1_erpc:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_cp_443-1_opc_ua_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_cp_443-1_opc_ua:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200al_im_157-1_pn_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200al_im_157-1_pn:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200m_im153-4_pn_io_hf_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200m_im153-4_pn_io_hf:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200m_im153-4_pn_io_st_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200m_im153-4_pn_io_st:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_hf_firmware:*:*:*:*:*:*:*:* 1 OR 4.2.0
cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_hf:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200mp_im155-5_pn_st_firmware:*:*:*:*:*:*:*:* 1 OR 4.1.0
cpe:2.3:h:siemens:simatic_et200mp_im155-5_pn_st:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200s_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200s:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_basic_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_basic:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_hf_firmware:*:*:*:*:*:*:*:* 1 OR 3.3.1
cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_hf:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200sp_im155-6_pn_st_firmware:*:*:*:*:*:*:*:* 1 OR 4.1.0
cpe:2.3:h:siemens:simatic_et200sp_im155-6_pn_st:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200ecopn_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200ecopn:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_et200pro_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_et200pro:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:im_154-3_pn_hf_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:im_154-3_pn_hf:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:im_154-4_pn_hf_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:im_154-4_pn_hf:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_mv440:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_mv420:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_pn\/pn_coupler_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_pn\/pn_coupler:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_rf180c_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_rf180c:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:simatic_rf600_firmware:*:*:*:*:*:*:*:* 1 OR 3.0
cpe:2.3:h:siemens:simatic_rf600:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:* 1 OR 1.3
cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:L/Au:N/C:N/I:N/A:C
  • Access Vector
  • NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • NONE
  • Confidentiality Impact
  • NONE
  • Integrity Impact
  • NONE
  • Availability Impact
  • COMPLETE
  • Base Score
  • 7.8
  • Severity
  • HIGH
  • Exploitability Score
  • 10
  • Impact Score
  • 6.9
CVSS Version 3
  • Version
  • 3.1
  • Vector String
  • CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • NONE
  • Availability Impact
  • HIGH
  • Base Score
  • 7.5
  • Base Severity
  • HIGH
  • Exploitability Score
  • 3.9
  • Impact Score
  • 3.6
References
Reference URL Reference Tags
https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf Vendor Advisory
https://www.us-cert.gov/ics/advisories/icsa-20-042-04 Third Party Advisory US Government Resource
History
Created Old Value New Value Data Type Notes
2022-05-10 15:43:36 Added to TrackCVE
2022-12-04 10:59:55 2020-02-11T16:15Z 2020-02-11T16:15:15 CVE Published Date updated
2022-12-04 10:59:55 2022-04-12T10:15:10 CVE Modified Date updated
2022-12-04 10:59:55 Modified Vulnerability Status updated
2023-04-11 14:08:32 2023-04-11T10:15:08 CVE Modified Date updated
2023-04-11 14:08:32 Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. Description updated