CVE-2019-10964

CVSS V2 Medium 5.8 CVSS V3 High 8.8
Description
In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed Paradigm 522/722 pumps – All versions,MiniMed Paradigm 522K/722K pumps – All versions, MiniMed Paradigm 523/723 pumps – Software versions 2.4A or lower, MiniMed Paradigm 523K/723K pumps – Software, versions 2.4A or lower, MiniMed Paradigm Veo 554/754 pumps – Software versions 2.6A or lower, MiniMed Paradigm Veo 554CM and 754CM models only – Software versions 2.7A or lower, the affected insulin pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
Overview
  • CVE ID
  • CVE-2019-10964
  • Assigner
  • ics-cert@hq.dhs.gov
  • Vulnerability Status
  • Modified
  • Published Version
  • 2019-06-28T21:15:11
  • Last Modified Date
  • 2020-08-24T17:37:01
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:medtronic:minimed_508_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_508:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_511_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_511:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_512_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_512:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_712_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_712:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_712e_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_712e:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_515_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_515:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_715_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_715:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_522_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_522:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_722_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_722:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_522k_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_522k:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_722k_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_722k:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_523_firmware:*:*:*:*:*:*:*:* 1 OR 2.4a
cpe:2.3:h:medtronic:minimed_paradigm_523:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_723_firmware:*:*:*:*:*:*:*:* 1 OR 2.4a
cpe:2.3:h:medtronic:minimed_paradigm_723:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_523k_firmware:*:*:*:*:*:*:*:* 1 OR 2.4a
cpe:2.3:h:medtronic:minimed_paradigm_523k:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_723k_firmware:*:*:*:*:*:*:*:* 1 OR 2.4a
cpe:2.3:h:medtronic:minimed_paradigm_723k:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_554_firmware:*:*:*:*:*:*:*:* 1 OR 2.6a
cpe:2.3:h:medtronic:minimed_paradigm_veo_554:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_754_firmware:*:*:*:*:*:*:*:* 1 OR 2.6a
cpe:2.3:h:medtronic:minimed_paradigm_veo_754:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_554cm_firmware:*:*:*:*:*:*:*:* 1 OR 2.7a
cpe:2.3:h:medtronic:minimed_paradigm_veo_554cm:*:*:*:*:*:*:*:* 0 OR 2.7a
AND
cpe:2.3:o:medtronic:minimed_paradigm_veo_754cm_firmware:-:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:medtronic:minimed_paradigm_veo_754cm:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:A/AC:L/Au:N/C:P/I:P/A:P
  • Access Vector
  • ADJACENT_NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • NONE
  • Confidentiality Impact
  • PARTIAL
  • Integrity Impact
  • PARTIAL
  • Availability Impact
  • PARTIAL
  • Base Score
  • 5.8
  • Severity
  • MEDIUM
  • Exploitability Score
  • 6.5
  • Impact Score
  • 6.4
CVSS Version 3
  • Version
  • 3.0
  • Vector String
  • CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Attack Vector
  • ADJACENT_NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • HIGH
  • Availability Impact
  • HIGH
  • Base Score
  • 8.8
  • Base Severity
  • HIGH
  • Exploitability Score
  • 2.8
  • Impact Score
  • 5.9
References
Reference URL Reference Tags
https://www.us-cert.gov/ics/advisories/icsma-19-178-01 Third Party Advisory US Government Resource
http://www.securityfocus.com/bid/108926 Third Party Advisory VDB Entry
History
Created Old Value New Value Data Type Notes
2022-05-10 16:33:09 Added to TrackCVE
2022-12-03 22:37:24 2019-06-28T21:15Z 2019-06-28T21:15:11 CVE Published Date updated
2022-12-03 22:37:24 2020-08-24T17:37:01 CVE Modified Date updated
2022-12-03 22:37:24 Modified Vulnerability Status updated