CVE-2018-7781

CVSS V2 Medium 4 CVSS V3 High 8.8
Description
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
Overview
  • CVE ID
  • CVE-2018-7781
  • Assigner
  • cybersecurity@se.com
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2018-07-03T14:29:01
  • Last Modified Date
  • 2019-10-03T00:03:26
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:schneider-electric:imps110-1_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imps110-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imps110-1e_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imps110-1e:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imps110-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imps110-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:ibps110-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:ibps110-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp1110-1_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp1110-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp1110-1e_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp1110-1e:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp1110-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp1110-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:ibp1110-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:ibp1110-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp219-1_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp219-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp219-1e_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp219-1e:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp219-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp219-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:ibp219-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:ibp219-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp319-1_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp319-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp319-1e_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp319-1e:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp319-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp319-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:ibp319-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:ibp319-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp519-1_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp519-1:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp519-1e_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp519-1e:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:imp519-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:imp519-1er:-:*:*:*:*:*:*:* 0 OR
AND
cpe:2.3:o:schneider-electric:ibp519-1er_firmware:*:*:*:*:*:*:*:* 1 OR 3.29.69
cpe:2.3:h:schneider-electric:ibp519-1er:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:L/Au:S/C:P/I:N/A:N
  • Access Vector
  • NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • SINGLE
  • Confidentiality Impact
  • PARTIAL
  • Integrity Impact
  • NONE
  • Availability Impact
  • NONE
  • Base Score
  • 4
  • Severity
  • MEDIUM
  • Exploitability Score
  • 8
  • Impact Score
  • 2.9
CVSS Version 3
  • Version
  • 3.0
  • Vector String
  • CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • LOW
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • HIGH
  • Availability Impact
  • HIGH
  • Base Score
  • 8.8
  • Base Severity
  • HIGH
  • Exploitability Score
  • 2.8
  • Impact Score
  • 5.9
References
History
Created Old Value New Value Data Type Notes
2022-05-10 07:44:17 Added to TrackCVE
2022-12-03 08:55:59 cybersecurity@schneider-electric.com cybersecurity@se.com CVE Assigner updated
2022-12-03 08:55:59 2018-07-03T14:29Z 2018-07-03T14:29:01 CVE Published Date updated
2022-12-03 08:55:59 2019-10-03T00:03:26 CVE Modified Date updated
2022-12-03 08:55:59 Analyzed Vulnerability Status updated