CVE-2018-13114

CVSS V2 High 7.5 CVSS V3 Critical 9.8
Description
Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
Overview
  • CVE ID
  • CVE-2018-13114
  • Assigner
  • cve@mitre.org
  • Vulnerability Status
  • Analyzed
  • Published Version
  • 2018-10-22T20:29:00
  • Last Modified Date
  • 2020-08-24T17:37:01
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:keruigroup:ypc99_firmware:*:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:keruigroup:ypc99:-:*:*:*:*:*:*:* 0 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:L/Au:N/C:P/I:P/A:P
  • Access Vector
  • NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • NONE
  • Confidentiality Impact
  • PARTIAL
  • Integrity Impact
  • PARTIAL
  • Availability Impact
  • PARTIAL
  • Base Score
  • 7.5
  • Severity
  • HIGH
  • Exploitability Score
  • 10
  • Impact Score
  • 6.4
CVSS Version 3
  • Version
  • 3.0
  • Vector String
  • CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
  • Attack Vector
  • NETWORK
  • Attack Compatibility
  • LOW
  • Privileges Required
  • NONE
  • User Interaction
  • NONE
  • Scope
  • UNCHANGED
  • Confidentiality Impact
  • HIGH
  • Availability Impact
  • HIGH
  • Base Score
  • 9.8
  • Base Severity
  • CRITICAL
  • Exploitability Score
  • 3.9
  • Impact Score
  • 5.9
References
Reference URL Reference Tags
https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html Exploit Third Party Advisory
History
Created Old Value New Value Data Type Notes
2022-05-10 16:29:26 Added to TrackCVE
2022-12-03 13:42:29 2018-10-22T20:29Z 2018-10-22T20:29:00 CVE Published Date updated
2022-12-03 13:42:29 2020-08-24T17:37:01 CVE Modified Date updated
2022-12-03 13:42:29 Analyzed Vulnerability Status updated