A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected product's update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
Overview
- CVE ID
- CVE-2018-10626
- Assigner
- ics-cert@hq.dhs.gov
- Vulnerability Status
- Modified
- Published Version
- 2018-08-10T18:29:00
- Last Modified Date
- 2019-10-09T23:32:56
Weakness Enumerations
CPE Configuration (Product)
CPE | Vulnerable | Operator | Version Start | Version End |
---|---|---|---|---|
AND | ||||
cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:* | 0 | OR | ||
AND | ||||
cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:* | 1 | OR | ||
cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:* | 0 | OR |
CVSS Version 2
- Version
- 2.0
- Vector String
- AV:A/AC:M/Au:S/C:P/I:P/A:N
- Access Vector
- ADJACENT_NETWORK
- Access Compatibility
- MEDIUM
- Authentication
- SINGLE
- Confidentiality Impact
- PARTIAL
- Integrity Impact
- PARTIAL
- Availability Impact
- NONE
- Base Score
- 3.8
- Severity
- LOW
- Exploitability Score
- 4.4
- Impact Score
- 4.9
CVSS Version 3
- Version
- 3.0
- Vector String
- CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N
- Attack Vector
- ADJACENT_NETWORK
- Attack Compatibility
- HIGH
- Privileges Required
- LOW
- User Interaction
- NONE
- Scope
- CHANGED
- Confidentiality Impact
- LOW
- Availability Impact
- NONE
- Base Score
- 4.4
- Base Severity
- MEDIUM
- Exploitability Score
- 1.3
- Impact Score
- 2.7
References
Reference URL | Reference Tags |
---|---|
https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01 | Third Party Advisory US Government Resource |
http://www.securityfocus.com/bid/105042 | Third Party Advisory VDB Entry |
Sources
Source Name | Source URL |
---|---|
NIST | https://nvd.nist.gov/vuln/detail/CVE-2018-10626 |
MITRE | https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2018-10626 |
History
Created | Old Value | New Value | Data Type | Notes |
---|---|---|---|---|
2022-05-10 17:06:51 | Added to TrackCVE | |||
2022-12-03 11:03:47 | 2018-08-10T18:29Z | 2018-08-10T18:29:00 | CVE Published Date | updated |
2022-12-03 11:03:47 | 2019-10-09T23:32:56 | CVE Modified Date | updated | |
2022-12-03 11:03:47 | Modified | Vulnerability Status | updated |