CVE-2012-5861

CVSS V2 High 7.5 CVSS V3 None
Description
Multiple SQL injection vulnerabilities on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 allow remote attackers to execute arbitrary SQL commands via (1) the inverterselect parameter in a primo action to dettagliinverter.php or (2) the lingua parameter to changelanguagesession.php.
Overview
  • CVE ID
  • CVE-2012-5861
  • Assigner
  • ics-cert@hq.dhs.gov
  • Vulnerability Status
  • Modified
  • Published Version
  • 2012-11-23T12:09:58
  • Last Modified Date
  • 2017-08-29T01:32:49
CPE Configuration (Product)
CPE Vulnerable Operator Version Start Version End
AND
cpe:2.3:o:sinapsitech:sinapsi_firmware:*:*:*:*:*:*:*:* 1 OR 2.0.2870
cpe:2.3:h:sinapsitech:esolar_duo_photovoltaic_system_monitor:-:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:sinapsitech:esolar_light_photovoltaic_system_monitor:-:*:*:*:*:*:*:* 1 OR
cpe:2.3:h:sinapsitech:esolar_photovoltaic_system_monitor:-:*:*:*:*:*:*:* 1 OR
CVSS Version 2
  • Version
  • 2.0
  • Vector String
  • AV:N/AC:L/Au:N/C:P/I:P/A:P
  • Access Vector
  • NETWORK
  • Access Compatibility
  • LOW
  • Authentication
  • NONE
  • Confidentiality Impact
  • PARTIAL
  • Integrity Impact
  • PARTIAL
  • Availability Impact
  • PARTIAL
  • Base Score
  • 7.5
  • Severity
  • HIGH
  • Exploitability Score
  • 10
  • Impact Score
  • 6.4
History
Created Old Value New Value Data Type Notes
2022-05-10 08:47:41 Added to TrackCVE